Seven signs your fuse box needs replacing

The short answer

A fuse box should be replaced if it has rewirable fuses, no RCD protection, a plastic or wooden enclosure that shows heat damage, or if it trips often, buzzes, or has no room for the new circuits you need.

1. It has rewirable fuses

If your board has pull-out fuse carriers with a strand of fuse wire across them, it is several decades old. Rewirable fuses react slowly, and they are easy to repair with the wrong rating of wire, which defeats their purpose.

2. There is no RCD

An RCD is the device with a button marked T or Test. It cuts the power in a fraction of a second if current leaks to earth, for example through a person. Old boards have none. If you cannot find a test button anywhere on your board, you do not have this protection.

3. It has a wooden back or sits in a wooden cupboard with scorch marks

Since 2016, consumer units fitted in homes have had to be made of non-combustible material, which in practice means metal. Older plastic boards are not illegal, but any sign of browning, melting or scorching needs looking at promptly.

4. Breakers trip often

Occasional tripping means the board is doing its job. Frequent tripping means something is wrong: an overloaded circuit, a faulty appliance, a wiring fault, or a breaker that has worn out.

5. It buzzes, crackles or feels warm

A consumer unit should be silent and cool. Noise or heat usually points to a loose connection, and loose connections cause fires. Do not wait on this one.

6. There is no room for what you want to add

EV chargers, electric showers, induction hobs, garden rooms and extensions all need their own circuit. If the board is full, or is not suitable for the protection a new circuit requires, it may be time to replace it.

7. An inspection has flagged it

If an EICR has given your consumer unit a C1 or C2 code, it needs dealing with. For landlords, that has to happen within 28 days.

What an upgrade involves

A typical domestic upgrade takes a day. The old board comes out, a new metal consumer unit goes in with RCD or RCBO protection and usually surge protection, and every circuit is tested. Replacing a consumer unit is notifiable under Part P of the Building Regulations, so make sure you receive an Electrical Installation Certificate and a Building Regulations compliance certificate when the work is finished.

Need a hand?

L M Electrical Ltd is a Hull-based electrical contractor covering Hull, Beverley, Brough, Goole and Barton-upon-Humber. Read more about our fuse box and consumer unit upgrades service, or call 07739 045702 for a free, no-obligation quote.

This guide is general information for properties in England and is not a substitute for an inspection of your own installation. Regulations change, so check the current rules before relying on them.

Need an electrician?

Fully qualified and insured. Call 07739 045702 for a free, no-obligation quote.